 marlow industries inc.(R)
Thermoelectric Cooler
Performance Values
Hot Side Temperature (C) Tmax (C-dry N2): Qmax (watts): Imax (amps): Vmax (vdc): AC Resistance (ohms): 27C 61 4.8 1.0 8.5 7.42 50C 69 5.4 1.0 9.6 ---
MI1013T
Mechanical Characteristics
Positive Lead Leads: 28 AWG (0.32) Bus Solid Tinned Copper Negative Lead
.518 [13.16]
.518 [13.16]
2.00 +/-.25 [50.80+/-6.35]
.095+/-.005 [2.41 +/-0.13]
Cold Side
.005 [0.13] .001 [0.03] .001 [0.03]
A
Ceramic Material: Alumina (AC) Millimeters are in [ ]
A
Ordering Options
MI1013T-01 MI1013T-02 MI1013T-03 both surfaces are metallized hot side exterior is metallized no metallization
* * * *
For example, and MI1013T with only the hot side metallized is specified as an MI1013T-02AC Pretinned metallized ceramic surface(s) with 117C solder. Thermistor mounted on edge of cold side ceramic. (Calibration available.) Elevated temperature burn-in with test data provided.
102-0015, Rev D
Thermoelectric Cooler
Performance Curves
Environment: One atmosphere dry nitrogen
80.0 60.0 T (C) 40.0 20.0 0.0 VOLTAGE (VDC) 8.0 6.0 4.0 2.0 0.0 0.0 0.2 0.4 0.6 0.8 CURRENT (AMPS) 1.0 Q=0 T=0 HEAT LOAD (WATTS) 0.00 0.50 1.00 1.50 2.00 2.50 3.00 3.50 4.00 4.50 80.0 60.0 T (C) 40.0 20.0 0.0 VOLTAGE (VDC) 8.0 6.0 4.0 2.0 0.0 0.0 0.2 0.4 0.6 0.8 CURRENT (AMPS) 1.0
MI1013T
HEAT LOAD (WATTS) 0.00 0.50 1.00 1.50 2.00 2.50 3.00 3.50 4.00 4.50 5.00
Q=0 T=0
For performance information in a vacuum or with hot side temperatures other than 27C or 50C, consult one of our Applications Engineers.
Installation
Recommended mounting methods: Bonding with thermal epoxy or soldering with metallized ceramics. For additional information, please refer to our TEC Installation Guide.
Operation Cautions
For maximum reliability, storage and operation below 85C in a non-condensing environment is recommended. To minimize thermal stress, use linear/proportional temperature control or a similar method rather than an ON/OFF method.
Marlow Industries, Inc. 10451 Vista Park Road Dallas Texas 75238-1645 TEL: 214-340-4900 FAX: 214-341-5212 Internet: http://www.marlow.com
Marlow Industries Europe Aberdeen House, South Road Haywards Heath West Sussex RH164NG UK TEL: +44 (0)1444-443404 FAX: +44 (0)1444-443334
Marlow Industries Asia 1-1-8-401 Uehara, Shibuya-ku Tokyo, Japan 151-0064 TEL: +81 (3) 5454-5280 FAX: +81 (3) 5454-5281
Copyright 2005, Marlow Industries, Inc. Marlow Industries reserves the right to change the design and specifications of products without notice. 102-0015, Rev D


▲Up To Search▲   

 
Price & Availability of MI1013T-01

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X